This is not the first time I’ve ranted about the previous owner’s wiring jobs, though I think they were on the other site (and I had a different username there).

His greatest hits include:

  • Above a drop ceiling in the basement, a wire that went into a metal box without a strain relief, so it eventually wore through (for whatever reason) and started shorting out. Since it was above the drop ceiling I had no idea why that breaker would occasionally trip, then reset without complaint. Also, there are other things on that circuit, but the offending wire was only live when the light switch in the room was on, so it was harder to diagnose. It wasn’t until we demolished the room that we found the problem…black marks on the box and wires and all.

  • A duct fan to route heat from the pellet stove into the master bedroom…with the wiring completely enclosed in the ceiling, with no access to the box. Said duct fan has started making noise, so I’m going to have to cut that ceiling open and replace it, and I’ll probably install one of those spring-loaded covers so there is access in the future.

  • A fascinating wiring job in the shed that is unnecessarily complicated and certainly a violation of the code on how many conductors can be in a box. I’m going to fix that some time this spring. This is actually a REALLY great one, so maybe I’ll post it as a comment.

On to today’s hilarity. A few weeks ago I noticed the UPS for my computer in the basement had a red light on the back warning of a wiring fault. I never noticed it before, or I did and forgot, and it’s not very bright, so you almost have to be looking for it to see it. Well, I got out one of those testers that you plug in, with three lights that diagnose the issue, and it showed no ground. Odd.

I checked the other two outlets on the same wall, the one closer to the panel tested fine, but the one on the other side of the outlet in question also showed an open ground.

Today I dug in to find out what was up. It turns out the ground was cut on both wires in the outlet the computer was using (supply from the previous outlet and the wire to the next outlet). It was not connected to the metal box or the outlet.

WHY WHY WHY? Why did he do this? I can’t fathom why you’d do this.

I replaced all three outlets on that wall with new ones and made sure the grounds were connected. Nothing really wrong with the original outlets and covers, but they were old and beige, and I like white.

Years ago I found an outlet in our closet that only had two prongs, no ground. The house was built in 1987, well after three prongs were standard. With some trepidation - what am I going to find here? - I opened it up and found that…there was a good ground there (to my relief) but he apparently just decided to use a two prong outlet. WHY? He had to have gone to special effort to find a two prong outlet to install. (Actually it is theoretically possible that was done by the builders, but everything else in the house is three prongs, and I can’t believe it would have passed inspection.)

  • limelight79@lemm.eeOP
    link
    fedilink
    arrow-up
    1
    ·
    9 months ago

    Yeah you’re probably right. Which reminds me, he was a bomb technician. And he had all of his fingers. So clearly he understood electricity for that purpose…