  • Thank you for responding and providing the link and info. The top comment in that reddit post has the same link I posted above.

    For the

    zpool import // find the ID of the NVME pool

    How did you find the ID of the NVME pool? I think is part of the problem I have where I see multiple partitions and not entirely sure which is the “boot” partition I should be pointing to. I think in your case, you’re pointing to the “data” partition, but this might help me eliminate one of my options.

    I’m also not sure how the raid1 plays into things since it seems like both physical drives seem to have the same partitions. Not sure if I can just point to one of the “boot” partitions on one of the drives and it’ll find it’s partner when it starts booting?




  • Prior to doing the Proxmox install, and prior to the PCIe bifurcation, I still was unable to see the drives directly in iDRAC/bios. What I’ve read online is Dell does this for “reasons” and they happen to sell an add-on card to let you directly access NVMe from PCIe.

    While I’m not ruling out the ZFS mirror issue, I don’t think it’s the cause of my problem considering both Clover and the Proxmox install debug can see the drives/partitions. I just don’t understand partition/device/boot structures and processes enough to make sense of what I’m seeing in the blkid/preboot results.

    Trying to find information about it online just gets me bad guides about making partitions. The Linux docs for blkid and fdisk also don’t seem to have the explanation of the results, just the arguments for the commands.


  • The server has 24x 2.5" bays. I have an old SSD drive that I figure I could use as a last resort to be the Proxmox boot drive and then just use the NVMe’s as storage.

    I was just hoping to have the Proxmox install/configuration in the NVMe RAID1 just for some minor safety in case a drive dies. From what I’ve read, this should be possible. I’m just lacking the knowledge to know what I’ve done wrong. (Mostly my lack of understanding the blkid results.)


  • The original plan is to use an SD card with Clover in read-only mode to bootload Proxmox running on the NVMe drives. (Read-only to prevent frying the SD card) This server has a built in SD Card slot Dell calls “vFlash” that you can actually remotely partition and configure. That’s where I was going to put the final configuration of Clover.

    How fast/often is Proxmox writing logging? It’s concerning that you say you had this fry some NVMes since that’s what I’m trying to do here. Is this a setting that you can adjust?


  • I don’t think the bifurcation is causing me issues. Before I enabled it, I wasn’t able to see the drives from iDRAC/Bios. From what I’ve been able to research, this is expected and Dell sells the “solution” to booting directly from them. (Add-in card that’s pretty pricey…)

    I do have an old SATA SSD that I’m considering slotting into one of the bays and using to boot. But I see that as a “last resort” option. I was hoping to have a bit of redundancy with the Proxmox install/configuration itself.

    I feel that there’s a solution to the current setup and I just lack the knowledge to fix it. Everything I’ve been able to find points to my current setup being able to work. I’m just being hindered by not understanding partition/device/boot structure.

    From what I understand, and what I saw during the Proxmox installation, if I can get past whatever part of the POST/boot process is preventing seeing the drives directly, I can use Clover to bootload from there. I’ve been able to boot into Clover just fine, and it was able to “see” the drives and partitions. I just don’t know which one should hold the Proxmox boot and if I’ve configured the Clover config correct.


  • From what I’ve read online, Dell does something similar. There’s some sort of card/add-on that can enable directly seeing and booting from PCIe but they are costly.

    This server has the internal USB and a build in SD slot accessible from the rear. (There’s also a dual card option like you mention for redundancy.)

    My plan was to get Clover working with USB, then use the vFlash SD slot to hold the Clover bootloader in read-only mode. This would hopefully prevent the SD card from dying quickly.



  • Ac5000@lemm.eetoSelfhosted@lemmy.worldMy self-hosted home setup
    link
    fedilink
    English
    arrow-up
    2
    ·
    edit-2
    1 year ago

    Thank you for posting this with the explanations and great visuals! I am wanting to upgrade to a setup almost identical to this and you’ve basically given me the bill of materials and task list.

    Anything you wish you had done differently or suggest changing/upgrading before I think about putting something similar together?